Publications by Danilatos et al.
Environmental Scanning Electron Microscopy
- Danilatos, G.D., and Robinson, V.N.E.
(1979) Principles of scanning electron
microscopy at high specimen pressures. Scanning 2:72-82.
- Danilatos, G.D. (1980a) An atmospheric scanning electron microscope
(ASEM). Scanning 3:215-217.
- Danilatos, G.D. (1980b) An atmospheric scanning electron microscope
(ASEM). Sixth Australian Conference on Electron Microscopy and Cell
Biology, Micron 11:335-336.
- Danilatos, G.D., Robinson, V.N.E., and
Postle, R. (1980) An environmental
scanning electron microscope for studies of wet wool fibres. Proc. Sixth
Quinquennial Wool Textile Research Conference, Pretoria, II:463-471.
- Danilatos, G.D. (1981a) The examination of fresh or living plant material
in an environmental scanning electron microscope. J. Microsc. 121:235-238.
- Danilatos, G.D. (1981b) Design and construction of an atmospheric or
environmental SEM (part 1). Scanning 4:9-20.
- Danilatos, G., Loo, S.K., Yeo, B.C., and
McDonald, A. (1981) Environmental and
atmospheric scanning electron microscopy of biological tissues. 19th
Annual Conference of Anatomical Society of Australia and New Zealand, Hobart,
J. Anatomy 133:465.
- Danilatos, G.D., and Postle, R. (1982a)
Advances in environmental and
atmospheric scanning electron microscopy. Proc. Seventh Australian Conf.
El. Microsc. and Cell Biology, Micron 13:253-254.
- Danilatos, G.D., and Postle, R. (1982b)
The environmental scanning electron
microscope and its applications . Scanning Electron Microscopy 1982:1-16.
- Danilatos, G.D., and Postle, R. (1982c)
The examination of wet and living specimens
in a scanning electron microscope. Proc. Xth Int. Congr. El. Microsc.,
Hamburg, 2:561-562.
- Danilatos, G.D. (1983a) Gaseous detector device for an
environmental electron probe microanalyzer .
Research Disclosure No. 23311:284.
- Danilatos, G.D. (1983b) A gaseous detector device for an environmental
SEM . Micron and Microscopica Acta 14:307-319.
- Danilatos, G.D., and Postle, R. (1983)
Design and construction of an atmospheric or
environmental SEM-2 . Micron 14:41-52.
- Danilatos, G.D. (1984) The gas as a
detection medium in the environmental SEM. Eighth Australian Conference on
Electron Microscopy, Brisbane, Australian Academy of Science, Abstracts:9.
- Danilatos, G.D., and Brancik, J.V.
(1984) A microinjector system in the environmental SEM. Eighth Australian
Conference on Electron Microscopy, Brisbane, Australian Academy of Science,
Abstracts:34.
- Danilatos, G.D., Denby, E.F., and
Algie, J.E. (1984) The effect of
relative humidity on the shape of Bacillus apiarius spores. Current
Microbiology 10:313-316.
- Danilatos, G.D. (1985) Design and construction of an atmospheric or
environmental SEM (part 3) . Scanning 7:26-42.
- Danilatos, G.D., and Brooks, J.H.
(1985) Environmental SEM in wool
research - present state of the art . Proc. 7th Int. Wool Textile Research
Conference, Tokyo, I:263-272.
- Danilatos, G.D. (1986a) "Environmental
and atmospheric SEM - an update". Ninth Australian Conference on Electron
Microscopy, Australian Academy of Science, Sydney, Abstracts:25.
- Danilatos, G.D. (1986b) Colour micrographs for backscattered electron
signals in the SEM . Scanning 8:9-18.
- Danilatos, G.D. (1986c) Environmental scanning electron microscopy
in colour. J. Microsc. 142:317-325.
- Danilatos, G.D. (1986d) Improvements on the gaseous detector
device. Proc. 44th Annual Meeting EMSA:630-631.
- Danilatos, G.D. (1986e) ESEM - A multipurpose surface electron
microscope. Proc. 44th Annual Meeting EMSA:632-633.
- Danilatos, G.D. (1986f) Beam-radiation effects on wool in the
ESEM. Proc. 44th Annual Meeting EMSA:674-675.
- Danilatos, G.D. (1986g) Specifications of a prototype
environmental SEM. Proc. XIth Congress on Electron Microscopy, Kyoto,
I:377-378.
- Danilatos, G.D. (1986h) Cathodoluminescence and gaseous
scintillation in the environmental SEM . Scanning 8:279-284.
- Danilatos, G.D., and Brancik, J.V.
(1986) Observation of liquid transport in the
ESEM. Proc. 44th Annual
Meeting EMSA:678-679.
- Danilatos, G.D. (1988a) Foundations of Environmental Scanning Electron
Microscopy . Advances in Electronics and Electron Physics, Academic Press,
Vol. 71:109-250.
- Danilatos, G.D. (1988b) Electron beam profile in the
ESEM. Proc. 46th Annual Meeting EMSA:192-193.
- Danilatos, G.D. (1988c) Contrast and resolution
in the ESEM. Proc. 46th Annual Meeting EMSA:222-223.
- Danilatos, G.D. (1989a) Surface chemistry in the ESEM. Pittsburgh
Conference and Exposition (Atlanta) 1989, Abstracts, paper No. 360.
- Danilatos, G.D. (1989b) Environmental SEM: a new instrument, a new
dimension. Proc. EMAG-MICRO 89, Inst. Phys. Conf. Ser. No 98, Vol.
1:455-458. (also Abstract in: Proc. Roy. Microsc. Soc. Vol. 24, Part 4, p.
S93).
- Danilatos, G.D. (1989c) Environmental scanning electron microscopy.
Proc. III Balkan Congress El. Microsc. (Ed. L. H. Margaritis), University of
Athens:1-4.
- Danilatos, G.D. (1990a) Design and construction of an environmental SEM
(part 4). Scanning 12:23-27.
- Danilatos, G.D. (1990b) Fundamentals of
environmental SEM. Eleventh Australian Conf. El. Microsc., University of
Melbourne, Abstracts.
- Danilatos, G.D. (1990c) Theory of the Gaseous Detector Device in the ESEM .
Advances in Electronics and Electron Physics, Academic Press, Vol. 78:1-102.
- Danilatos, G.D. (1990d) Mechanisms of detection and imaging in the
ESEM . J. Microsc. 160:9-19.
- Danilatos, G.D. (1990e) Equations of charge distribution in the ESEM .
Scanning Microscopy, Vol 4, No. 4:799-823.
- Danilatos, G.D. (1990f) Detection by induction in the environmental
SEM. Electron Microscopy 1990, Proc. XIIth Int. Congr. El. Microsc. (Ed.
Peachey and Williams), San Francisco Press, Vol. 1:372-373.
- Danilatos, G.D. (1991a) Review and outline of environmental SEM at
present . J. Microsc. 162:391-402.
- Danilatos, G.D. (1991b) Gas flow properties in the environmental SEM .
Microbeam Analysis-1991 (Ed. D G Howitt), San Francisco Press, San
Francisco:201-203.
- Danilatos, G.D. (1992a) Gas flow in the
ESEM. Proc. ACEM-12 & ANZSCB-11, Uni. of Western Australia, Perth:57.
- Danilatos, G.D. (1992b) Gas-flow field in the environmental SEM .
Proc. 50th Annual Meeting EMSA (Eds. GW Bailey, J Bentley and JA Small), San
Francisco Press, San Franciso:1298-1299.
- Danilatos, G.D. (1992c) Secondary-electron imaging by
scintillating gaseous detection device . Proc. 50th Annual Meeting EMSA (Eds. GW
Bailey, J Bentley and JA Small), San Francisco Press, San Franciso:1302-1303.
- Danilatos, G.D. (1993a) Environmental
scanning electron microscope-some critical issues
. Scanning Microscopy
International, Supplement 7, 1993:57-80.
- Danilatos, G.D. (1993b) Environmental scanning electron microscope:
A new tool for inspection and testing. The 6th International
MicroProcess Conference, Micoprocess '93:102-103.
- Danilatos, G.D. (1993c) Universal ESEM. Proc. 51st Annual Meeting
MSA, (Eds. GW Bailey and LC Rieder), San Francisco Press, San
Francisco:786-787.
- Danilatos, G.D. (1993d) Introduction to
ESEM instrument. Microsc. Microsc. Res.
Technique 25:354-361.
- Danilatos, G.D. (1993e) Bibliography of
environmental scanning electron microscopy. Microsc. Res. Technique 25:529-534.
- Danilatos, G.D. (1994) Environmental scanning electron microscopy
and microanalysis , Mikrochimica Acta 114/115:143-155.
- Danilatos GD (1997) Environmental Scanning Electron
Microscopy . In-Situ Microscopy in Materials Research, ed. PL Gai, Kluwer
Academic Publishers, Dordrecht, pp. 14-44.
- Danilatos GD (2000a) Radiofrequency gaseous
detection device . Microsc. Microanal.
6:12-20
- Danilatos GD (2000b) Reverse flow pressure
limiting aperture . Microsc. Microanal.
6:21-30
- Danilatos GD, Philips MR and Nailon JV
(2000c) Electron beam loss in commercial ESEM .
The 16th Australian
Conference on Electron Microscopy, Canberra, Abstracts:81-82.
- Danilatos GD (2000d) Direct simulation Monte
Carlo study of orifice flow. Rarefied Gas Dynamics: 22nd Intern.
Symp., Sydney, (Eds. TJ Bartel and MA Gallis), Am. Inst. Phys., AIP Conference
Proceedings, Vol. 585, pp. 924-932. VIEW
JOURNAL ABSTRACT.
- Danilatos GD, Philips MR and Nailon
JV (2001) Electron
beam loss at the high-vacuum-high-pressure boundary in the environmental
scanning electron microscope. Microsc. and Microanal. 7, 397-406.
- Danilatos GD (2009) Optimum
beam transfer in the environmental scanning electron microscope. J.
Microsc. 234:26-37 .
- Danilatos GD (2010). Optimising the beam transfer
in ESEM. 21st Australian Conference on Microscopy & Microanalysis,
Brisbane, Australia, Abstracts p189.
- Danilatos GD, Rattenberger J and Dracopoulos V (2011a)
Beam
transfer characteristics of a commercial environmental SEM and a low
vacuum SEM . J. Microsc. 242, 166-180.
- Danilatos GD (2011b) Figure
of merit for environmental SEM and its implications. J. Microsc. 244,
159-169.
- Danilatos GD (2012) Backscattered
electron detection in environmental SEM. J. Microsc. 245, 171-185.
- Danilatos GD (2012) Velocity
and ejector-jet assisted differential pumping: Novel design stages for
environmental SEM. Micron, 43, 600-611.
- Danilatos GD (2013)
Implications of the figure of merit in environmental SEM, Micron 44,
143-149
- Dracopoulos V and Danilatos GD (2013) ESEM
modifications to LEO SUPRA 35 VP FESEM, Micron 44, 238-245.
- Danilatos GD (2013) Electron
scattering cross-section measurements in ESEM. Micron 45, 1-16.
- Danilatos G, Kollia M, Dracopoulos V (2015) Transmission
environmental scanning electron microscope with scintillation gaseous
detection device. Ultramicroscopy 150,
44-53. doi:10.1016/j.ultramic.2014.11.010
- Oral M, Nedela V and Danilatos GD (2015) Dynamic
correction of higher-order deflection aberrations in the environmental
SEM
.
Microscopy and Microanalysis 06/15; 21 (S4): 194-199. DOI: DOI:10.1017/S143192761
Gravity
1. Danilatos Gerasimos (2020).Novel quantitative push gravity theory poised for
verification
.
(Version v7). Zenodo.
http://doi.org/10.5281/zenodo.4284106
Publications from Ph.D. Thesis on viscoelasticity
- Danilatos GD (1977) Dynamic Mechanical Properties of Keratin Fibres. Ph.D.
Thesis, University of NSW, Sydney, Australia.
- Danilatos G and Feughelman M (1976) The internal dynamic mechanical properties
of a -keratin fibers during moisture
sorption. Tex. Res. J. 46:845-846.
- Danilatos G and Feughelman M (1979) Dynamic mechanical properties of
a -keratin fibres during
extension. J. Macromol. Sci.-Phys. B16(4):581-602.
- Danilatos G and Feughelman M (1980) The microfibril-matrix relationships
in the mechanical properties of keratin fibers. Text. Res. J. 50:568-574.
- Danilatos GD (1980) Design of a fibre
viscoelastometer. J. Phys. E: Sci. Instrum. 13:1093-1098.
- Danilatos GD and Postle R (1981a) Dynamic mechanical properties of keratin
fibres during water absorption and desorption. J. Appl. Pol. Sci.
26:193-200.
- Danilatos GD and Postle R (1981b) Low-strain dynamic mechanical
properties of keratin fibres during water absorption. J. Macromol.
Sci.-Phys. B19(1):153-165.
- Danilatos G and Postle R (1981c) Dynamic mechanical measurements on some
man-made fibres. J. Text. Inst. 72:90-92.
- Danilatos GD and Postle R (1983) The time-temperature dependence of the
complex modulus of keratin fibres. J. Appl. Pol. Sci. 28:1221-1234.
- Feughelman M, Danilatos GD and Dubro D (1980) Observations on the
mechanical properties of microfibrils and matrix in a -keratins. Fibrous
Proteins: Scientific, Industrial and Medical Aspects, edited by Parry DAD and
Creamer LK, Vol. 2, Academic Press, London.
ESEM Home || ESEM
Research Laboratory||History ||Publications||Patents|| Danilatos||Commercial ESEM|| Subject
index||Public Images ||contact